Which node control the ringing timer in a VoLTE call?

+1 vote
459 views

I would like to know about which node control the ringing timer in a VoLTE call? And what are the parameters which are used to control this?

posted Jun 25, 2014 by anonymous

Share this question
Facebook Share Button Twitter Share Button LinkedIn Share Button

1 Answer

0 votes

The Media Resource Function (MRF) provides media related functions such as media manipulation (e.g. voice stream mixing) and playing of tones and announcements.

Each MRF is further divided into a media resource function controller (MRFC) and a media resource function processor (MRFP).

The MRFC is a signalling plane node that interprets information coming from an AS and S-CSCF to control the MRFP
The MRFP is a media plane node used to mix, source or process media streams. It can also manage access right to shared resources.
The Media Resource Broker (MRB) is a functional entity that is responsible for both collection of appropriate published MRF information and supplying of appropriate MRF information to consuming entities such as the AS. MRB can be used in two modes:

Query mode: AS queries the MRB for media and sets up the call using the response of MRB
In-Line Mode: AS sends a SIP INVITE to the MRB. The MRB sets up the call

answer Jun 8, 2015 by Anand Yadav
Similar Questions
+1 vote

Which of the network node initiates dedicated bearer creation for the VoLTE call ?

0 votes

In IMS VoLTE setting of a telecom network, what part/field of which type of packet (SIP, SDP, others...) gives authentic information of MSISDN-IP mapping? From a sample traffic, I need to find out information from control traffic about what IP is assigned to what phone number. In the sample traffic, I see a lot of protocols (SIP, SDP, RTP, DIAMETER, ISUP, ....). I require to find out IPs assigned to phone numbers. I know RTP flows between end devices (phones), but I need to find out IPs before the call is established...

+4 votes

In LTE network, PGW generates the charging records and sends to the OCS or OFCS node of the billing domain.
Does PGW take care of VoLTE charging or any other node such as S-CSCF or P-CSCF take care ?

0 votes

Is it mandatory that for a UE in VOLTE call and data IP Address must be different (different bearer)

...